How the model works

Assumptions, validation scope & known limits

What has been checked, what is idealized and what the model cannot claim.

Overview

Circulation Studio is literature-informed educational software using synthesized hemodynamic data. It is not validated for clinical decision making or patient care. A plausible response, passing test or cited mechanism does not establish patient-specific predictive accuracy.

Three kinds of content coexist: established definitions/equations; literature-informed directional relationships; and original numerical/graphical teaching assumptions. The latter include phenotype endpoints, interaction gains, timing, response bounds, error demonstrations and successful-treatment scenarios.

What automated checks establish

Tests check finite numerical results, pressure/flow identities, lesion-grade behavior, flow conservation, timing consistency, treatment exceptions, search/navigation and selected regressions. Source-catalog checks ensure new clinical links are recorded. These are software and internal-consistency checks.

The 13 September 2026 multi-valve/medication/ventilation audit exercised 238,260 configurations and 9,828 sampled LV/RV respiratory-loop checks. It covered a defined matrix, not every continuous input combination or every clinical presentation. The dated audit report describes that scope; later content should not imply a new clinical validation study.

Major idealizations

  • Settled drug, fluid and procedure endpoints; no general pharmacokinetic, cumulative fluid, renal or recovery-time model.
  • Selected adult disease phenotypes; no patient-specific anatomy, age, measured compliance, vascular impedance or body-size calibration across all modules.
  • Deterministic rhythm patterns and chosen rescue responses; no stochastic arrhythmia-risk, conduction-network or electrophysiology solver.
  • Synthetic pressure contours and PV/echo volume; no measured conductance volume, Doppler, coronary flow or myocardial energetics.
  • Single-compartment ventilation, fixed transmission/gas assumptions and bounded oxygen admixture; no regional lung or comprehensive acid–base model.
  • Illustrative support flow and shunt geometry; no complete transient circuit accumulation, cannula streaming, hemolysis or regional oxygenator mixing.
  • Reference/alert landmarks and success/error examples; no validated risk score, therapy recommendation or probability of adverse events.

How to use a surprising result

Compare baseline targets with final sampled values, confirm units and respiratory phase, identify native versus total/device flow, and inspect all selected pathologies and treatments. Check whether a number is measured from the trace, a formula estimate or a schematic proxy.

If the result contradicts flow balance, changes solely with viewport size, invents unavailable measurements or loses a lesion after another is added, that is a candidate software error. If it is an intentionally bounded extrapolation, it still needs its limitation stated. Documentation is not a reason to excuse a demonstrated bug.

Keeping the reference current

The model reference links every library module to a topic in a coverage inventory. Tests check that a newly added module has a documentation home, that article/section links resolve, and that section text and tables participate in search. Parameter tables reuse exported definitions where practical.

Coverage means the implementation has a documented home, not that every coefficient has been clinically validated. Changes to model behavior require an update to the relevant article, assumptions and references as well as numerical regression checks.